What is the reason for water leakage in a closed cooling tower?

Author:  Views:  Time:2025-09-15
What is the reason for water leakage in a closed cooling tower?

  Closed cooling towers are suitable for various cooling systems that require high circulating water quality, and have application prospects in power, chemical, steel, food, and many industrial fields. A closed cooling tower is a comprehensive product that combines aerodynamics, thermodynamics, fluid mechanics, chemistry, biochemistry, materials science, and other disciplines. Water quality is a multivariate function, while cooling is a comprehensive process involving multiple factors, variables, and influences.cN8Cooling tower noise reduction treatment manufacturer

  Water leakage is one of the common faults of closed cooling towers, but why do closed cooling towers leak? Let's take a look together.cN8Cooling tower noise reduction treatment manufacturer

  ① Leakage at the junction of the tower body and the water basin: When assembling a closed cooling tower, apply glue between the galvanized steel plates for compaction and sealing. Long term operation, the impact of water spray, deformation of the sink, and the dropping of sealant can all cause water leakage at the connection. Due to the concentration of water spray at the bottom of the pool, the leaking water needs to be continuously replenished with water spray.cN8Cooling tower noise reduction treatment manufacturer

  ② Leakage of connecting pipes: When arranging pipelines, it is necessary to connect some flanges and elbows. When connecting, a sealing ring is added between the two connectors. The main reason is that the pipeline connection is not firm, and damaged or displaced sealing rings can lead to weak seals and water leakage.cN8Cooling tower noise reduction treatment manufacturer

  ③ Corrosion and leakage of the water collection tank: Due to long-term use and the high pH of the water used, the environment and water quality may corrode the materials of the water collection tank. The thickness of the storage tank is uneven, and damage and water leakage may occur in the thinner parts. Leakage will increase water consumption, exacerbate environmental pollution, and accelerate the corrosion of other parts, forming a vicious cycle.cN8Cooling tower noise reduction treatment manufacturer

  The above is an introduction to the causes of water leakage in closed cooling towers, hoping it can be helpful to everyone.cN8Cooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/667.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba