The market price of closed cooling towers is basically relatively expensive. Some manufacturers are reluctant to purchase closed cooling towers in order to save costs, but can this ensure that the equipment in the manufacturers operates under normal conditions?
The closed cooling tower is a shell-and-tube heat exchanger placed in the tower, with the help of the heat exchange of circulating gas, spray water and circulating water to ensure the cooling effect. The following is a brief introduction to the maintenance of the closed cooling tower of the Kangming closed cooling tower for you.
Various noises flood the environment around us. In cities, noisy human voices and noises have become one of the public hazards that pollute the human social environment and become the three major pollution sources alongside air pollution and water pollution. Teling Air Conditioning is committed to cooling tower noise reduction projects.
Due to the use of T2 copper tubes and stainless steel heat exchangers, the closed cooling tower adopts aluminum alloy cooling fans and evaporative condensers for dual heat dissipation, and closed cooling liquid circulation. It is widely used in petroleum, chemical, foundry, thermoelectric and other industries. .
Cooling tower noise control countermeasures: According to the installation conditions of the cooling tower, the sound value is somewhat different. If there are noise requirements, please consult the cooling tower manufacturer in advance.
There is a big difference between using a cooling tower in winter and using it in summer. In summer, the environment temperature is high, so the heat exchange will be affected, and the temperature of the spray still cannot drop. The cooling tower temperature is high in summer, and the solution is difficult to cool down.
Precautions for cooling towers during operation and rest in winter: 1) Drain circulating water and spreading water. 2) In the case of a closed type, please open the circulating water drain, exhaust port, and drain valve of the diffuser water pump.
Some introductions of cooling tower manufacturers for cooling tower maintenance, setting up the site, and cooling heat-resistant temperature
What is the calculation method for the water supply of the air conditioning cooling tower? Water loss by evaporation (E) E = Q/600 = (T1-T2)×L/600; E represents the amount of evaporated water (kg/h); Q represents the heat load (Kcal/h); 600 represents the latent heat of evaporation of water (Kcal /h); T1 represents the water temperature (℃)
How many water pumps does a closed cooling tower need? There is no immediate response to this question, because in the case of the overall design of the fluid cooling tower, in the refrigeration plan presented by the customer, it is generally carried out with water pumps based on specific conditions.