What are the impacts of poor water quality on closed cooling towers?

Author:  Views:  Time:2025-10-28
What are the impacts of poor water quality on closed cooling towers?

  What are the impacts of poor water quality on closed cooling towers?FtCCooling tower noise reduction treatment manufacturer

  If the water quality is poor, it will have a significant impact on the cooling tower, causing a series of problems and additional maintenance costs. This article provides a detailed explanation of the impact that poor water quality can have on cooling towers. If you are unsure, come and learn more!FtCCooling tower noise reduction treatment manufacturer

  1. Scale formation: Regardless of whether it is an open cooling tower or a closed cooling tower, scale will definitely be formed. Scale formation in open cooling towers is mainly concentrated on the packing, while in closed cooling towers, scale formation is mainly concentrated on the outer wall of the condenser, and some may also adhere to the inner wall of the cooling tower. Scale is highly alkaline and can be corrosive to the walls, condenser, and packing of cooling towers.FtCCooling tower noise reduction treatment manufacturer

  2. Damaged packing: The scale generated is usually attached to the surface of the packing, and the weight of the scale is relatively large. Over time, it can cause the packing to be torn, damaged, and affect normal use. If necessary, it needs to be replaced.FtCCooling tower noise reduction treatment manufacturer

  3. Impact on heat dissipation: Scale adhering to the packing and the surface of the condenser can affect the heat dissipation and ventilation effects of a closed cooling tower. The circulating wind mainly flows through the gaps between the packing and the condenser for heat exchange, and scale will occupy a part of the space, reducing ventilation. In addition, scale will affect the heat dissipation effect of the packing and condenser.FtCCooling tower noise reduction treatment manufacturer

  4. Blocking the sprinkler head: The main function of the sprinkler head is to atomize and spray water evenly. Impurities will definitely block the sprinkler head, causing uneven spraying in the space, resulting in some dry spots or partial drying of the filling material. In this case, high heat can cause the cooling tower to catch fire.FtCCooling tower noise reduction treatment manufacturer

  5. Damaged water pump: The water pump is the main power system for spraying water. If there is sludge, it is usually sucked into the water pump, which will cause blockage of the water pump, resulting in insufficient circulating water volume, heating, weak power and other problems.FtCCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/753.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba