Solution to the Failure of Closed Cooling Tower

Author:  Views:  Time:2025-10-27
Solution to the Failure of Closed Cooling Tower

  Solution to the Failure of Closed Cooling TowerW1oCooling tower noise reduction treatment manufacturer

  1: Insufficient flow of cooling towerW1oCooling tower noise reduction treatment manufacturer

  There are many reasons for insufficient flow in cooling towers, and the most common ones may be belt slippage, mismatched power speed, and inappropriate installation angle of axial flow pump blades.W1oCooling tower noise reduction treatment manufacturer

  Solution: The belt of the cooling tower needs to be inspected and replaced at regular intervals. In the daily maintenance of the cooling tower fan, the inspection and adjustment of the belt position should be a routine inspection item. At the same time, if there is oil contamination in the belt, it will also affect the use of the belt. If there is oil contamination in the belt during inspection, it needs to be cleaned in a timely manner. When the installation angle of the impeller cannot be adjusted, the method of replacing the blades can be used to solve this problem.W1oCooling tower noise reduction treatment manufacturer

  2: Overheating of water pumpW1oCooling tower noise reduction treatment manufacturer

  The gap between the cover plates of the rolling bearings or brackets is too small, the tape is too tight, the quality of the lubricating oil is poor, and the water pump of the cooling tower will overheat. There are many ways to solve this problem.W1oCooling tower noise reduction treatment manufacturer

  Solution: Gaskets can be installed between the bracket and bearings of the cooling tower, and the concentricity between the shaft pump and the two shafts can be adjusted. In order to ensure the normal operation of the cooling tower, the relevant oil should meet certain requirements and be selected according to a certain model.W1oCooling tower noise reduction treatment manufacturer

  3: Motor overheatingW1oCooling tower noise reduction treatment manufacturer

  The main reason for motor overheating is the excessive load on the motor or the mismatch between motor power and equipment operation.W1oCooling tower noise reduction treatment manufacturer

  Solution: Before installation and during use, it is necessary to regularly check the circuit pressure and current resistance of the cooling tower. When the current resistance through the cooling tower equipment increases instantly, it will cause the current to decrease, which will lead to motor overheating. During use, it is necessary to check the circuit. If the current is unstable, adjustments need to be made to the circuit.W1oCooling tower noise reduction treatment manufacturer

  The situation of mismatched power is quite difficult to solve in later use, which is called the situation of a small horse pulling a large car. The occurrence of this situation is actually related to the consumer's choice. When choosing, the parameters of these powers should be balanced to avoid a mismatch between speed and power. The relevant production units actually need to check for consumers during the design process, rather than arbitrarily matching motors and equipment, which can lead to situations where the power cannot be matched.W1oCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/749.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba