Technical description of square cross flow low noise cooling tower

Author:Trlon  Views:  Time:2021-11-04
Technical description of square cross flow low noise cooling tower

  1. The main technical parameters and equipment quantity of the low-noise square cross-flow cooling tower are shown in the equipment table of the construction drawing.twVCooling tower noise reduction treatment manufacturer

  The role of the cooling tower is: the waste heat generated in the industrial production or refrigeration process is generally taken away through the cooling water. The role of the cooling tower is to exchange heat between the cooling water carrying the waste heat and the air in the tower, so that the waste heat is transferred to the air and dispersed into the atmosphere. Mainly used in air conditioning cooling systems, refrigeration series, injection molding, tanning, foaming, power generation, steam turbines, aluminum profile processing, air compressors, industrial water cooling and other fields. It is mostly used in air conditioning cooling, freezing, and plastic chemical industries.twVCooling tower noise reduction treatment manufacturer

  1. Low-noise square cross-flow cooling tower, the main technical parameters of the equipment.twVCooling tower noise reduction treatment manufacturer

  1: Inlet water temperature (t1)-refers to the temperature of the circulating water at the entrance of the cooling tower. The national standard requires 37.twVCooling tower noise reduction treatment manufacturer

  2: Outlet water temperature (T2)-refers to the circulating water temperature at the outlet (or bottom basin) of the cooling tower, and the national standard requires 32.twVCooling tower noise reduction treatment manufacturer

  3: Water temperature drop (t)-refers to the temperature difference between the inlet and outlet circulating water of the cooling tower, which is required by the national standard 5.twVCooling tower noise reduction treatment manufacturer

  4: Wet bulb temperature (TWB)-refers to the amount of water vapor in the air. Usually, the wet bulb temperature is measured by relative humidity, which reflects how close the air is to saturation. When the relative humidity is equal to 1, the air is saturated. When the relative humidity is less than 1, the air is dry and the moisture is easy to evaporate. When the relative humidity is equal to zero, it means that there is no water vapor in the air. The relative humidity in the northwest is relatively low and the air is relatively dry, while the relative humidity and air in the southeast coastal areas are relatively high. The national standard is 28 (about 75% relative humidity), if it is 27, the relative humidity is about 70%.twVCooling tower noise reduction treatment manufacturer

  5: Dry bulb temperature (TDB)-the air temperature, the national standard requires 31.5.twVCooling tower noise reduction treatment manufacturer

  6: Cooling width (△T)---refers to the difference between the temperature of the circulating water at the outlet of the cooling tower and the temperature of the wet bulb. The larger the cooling range, the better the heat dissipation effect of the cooling tower, and vice versa.twVCooling tower noise reduction treatment manufacturer

  7: Atmospheric pressure (P0)-refers to the pressure generated by the air on the earth, a standard atmospheric pressure is 1.013×105Pa,twVCooling tower noise reduction treatment manufacturer

  2. The composition range of the cooling tower:twVCooling tower noise reduction treatment manufacturer

  Each cooling tower shall include a tower, a supporting frame, a damping device, a steel casing, a fan drive system, an external air deflector, and a fan vibration cut-off switch. Inlet windows, splash baffles, water receivers, fillers, hot water distribution systems, cold water collection trays and filters, inspection doors, automatic water replenishment devices, overflow and drain outlets of submerged water trays, electric heaters and supporting facilities The chassis water temperature and water level controller. Provide, water inlet interface. The national standard flange and the balance connecting pipe interface between the tower tube and the oil injection port are reserved.twVCooling tower noise reduction treatment manufacturer

  3. Cooling tower: technical performance requirements for main components.twVCooling tower noise reduction treatment manufacturer

  1. Cooling tower properties:twVCooling tower noise reduction treatment manufacturer

  The supporting cooling tower should meet the long-term operation needs of the air conditioning system, strictly meet the needs of continuous operation all-weather, and meet the refrigeration and heat exchange needs of the refrigerator under the design outdoor wet bulb temperature conditions to ensure that the refrigeration system can be normal and efficient under any conditions under the design conditions , Reliable operation. The key materials that are immersed in water for a long time include loose water fillings. The water collecting tray, hot water pan and water distribution system should ensure the corrosion resistance and durability required for long-term operation.twVCooling tower noise reduction treatment manufacturer

  2. Cooling tower motor:twVCooling tower noise reduction treatment manufacturer

  The fan motor adopts a fully enclosed, three-phase squirrel-cage cooling tower special motor, double waterproof vapor seal, the motor protection level is not less than IP55, insulation level f, and temperature rise level B.twVCooling tower noise reduction treatment manufacturer

  3. Cooling tower fan:twVCooling tower noise reduction treatment manufacturer

  The fan should be a high-performance axial flow fan with aluminum alloy impellers, equipped with an outlet duct, and must be an external duct to ensure ventilation efficiency. The top is equipped with a protective cover to prevent foreign matter from entering the tower, and it should be a low-noise fan.twVCooling tower noise reduction treatment manufacturer

  4. Cooling tower bearings:twVCooling tower noise reduction treatment manufacturer

  The fan and steel shaft are supported by ball bearings, with heavy-duty self-calibration, moisture-proof seal and integral ring housing.twVCooling tower noise reduction treatment manufacturer

  5. Fan drive:twVCooling tower noise reduction treatment manufacturer

  Belt drive is used. The drive belt is not allowed to adopt multiple split forms, and should be a single-piece multi-slot conjoined belt. The belt material is a high-strength neoprene polyester material with built-in reinforcing materials, which has the ability to resist aging and water corrosion.twVCooling tower noise reduction treatment manufacturer

  The above is the introduction of the square cross-flow low-noise cooling tower brought by the cooling tower manufacturer Teling Air Conditioning. If you have more cooling tower holiday needs, you can continue to pay attention to us.twVCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/555.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba