What is a closed cooling tower recirculation system?

Author:  Views:  Time:2025-09-16
What is a closed cooling tower recirculation system?

  A closed cooling tower is a device that uses water as a circulating coolant to absorb heat from the device and discharge it into the atmosphere to reduce water temperature. Its cooling is achieved by exchanging cold and heat between water and air to generate steam, which evaporates to take away heat. The evaporative heat dissipation device realizes the principles of evaporative heat dissipation, convective heat transfer, and evaporation. Radiant heat transfer can dissipate waste heat generated in industry, refrigeration, and air conditioning to lower water temperature and ensure normal system operation. This device is usually barrel shaped, hence it is called a closed cooling tower.H2MCooling tower noise reduction treatment manufacturer

  The fan recirculation system of a closed cooling tower can be regarded as an important equipment, which also accounts for a large proportion of equipment quantity, maintenance work, and power consumption in the management of circulating water equipment. However, when the total number of personnel in the workshop is set at 57%, the total equipment maintenance is basically around 26%. In fact, based on the current situation, they still have about 20% of electricity consumption. In this way, the energy saving or related efficiency loss of the closed cooling tower fan can be increased, and the normal operation of the equipment cycle can be guaranteed for a long time.H2MCooling tower noise reduction treatment manufacturer

  It should fill the height of the top or bottom of the fan according to the actual situation, which is equal to or greater than 0.2 times the diameter of the fan. When the air contracts, a portion of the height is basically located on these surfaces. The selection should be based on different regulations, and at the same time, when the air at the top of the closed cooling tower shrinks, it is basically packaged on the upper surface. When the angle is less than 90 degrees, there are periodic guidelines. In addition, the angle between the top of the air contraction part and the top of the collector is basically 90 to 110 degrees.H2MCooling tower noise reduction treatment manufacturer

  The closed cooling tower is equipped with two different air intakes, but the backflow of these air intakes is basically equipped with a baffle. The bottom of the closed cooling tower is supported by material at a distance of 200 from the upper edge of the baffle. When the millimeter is 300 millimeters, there is lower edge support. Here, it will also be set below the water level and above the relevant cooling tower to avoid air circulation short circuits.H2MCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/671.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba