Key points to note before operating the cooling tower

Author:  Views:  Time:2025-09-26
Key points to note before operating the cooling tower

  Key points to note before operating the cooling towerG7dCooling tower noise reduction treatment manufacturer

  1. During installation, please refer to the "Pipeline Installation Instructions" and select the appropriate pipeline length, number of gate valves, number of bends, links, direct pipe joints, and so on Other hose fittings should be determined based on the actual situation in the required field, and do not forget the possibility and necessity of their installation.G7dCooling tower noise reduction treatment manufacturer

  2. The connection of the circuit can refer to our company's "Motor Wiring and Drainage Instructions".G7dCooling tower noise reduction treatment manufacturer

  3. Prepare the pump start-up work in advanceG7dCooling tower noise reduction treatment manufacturer

  Rotate the blades of the motor to ensure that its impeller can operate flexibly; No obstruction, poor friction or malfunction.G7dCooling tower noise reduction treatment manufacturer

  Open the inlet valve and intake valve to allow the liquid to cover the entire internal space of the pump, and then close the intake valve;G7dCooling tower noise reduction treatment manufacturer

  Add pump oil to the surface of the mechanical seal for lubrication;G7dCooling tower noise reduction treatment manufacturer

  At the moment of starting the motor, ensure that the direction of motor operation is correct;G7dCooling tower noise reduction treatment manufacturer

  Start work:G7dCooling tower noise reduction treatment manufacturer

  Fully open the inlet (or oil) valve;G7dCooling tower noise reduction treatment manufacturer

  Close the drainage valve of the pipeline;G7dCooling tower noise reduction treatment manufacturer

  Start the motor to ensure that the water pump is working properly;G7dCooling tower noise reduction treatment manufacturer

  Adjust the drainage valve to fully meet the operating conditions of the pump If a flow meter or pressure gauge is installed at the outlet of the pump, the open outlet valve should be adjusted to allow the pump to operate within the quality parameter range listed in its rate table. During this period, the current of the motor should be tested to ensure that the current setting does not exceed its power, in order to prevent overloading of the pump and burning out the motor.G7dCooling tower noise reduction treatment manufacturer

  Check the leakage of mechanical seals, which should usually be controlled to less than 3 drops per minute;G7dCooling tower noise reduction treatment manufacturer

  Check the temperature rise and fall of the motor and bearings to ensure that their temperature is ≤ 70 ℃.G7dCooling tower noise reduction treatment manufacturer

  Stop working:G7dCooling tower noise reduction treatment manufacturer

  Close the inlet and outlet valves of the pipeline;G7dCooling tower noise reduction treatment manufacturer

  Stop the motor and turn off the power;G7dCooling tower noise reduction treatment manufacturer

  If the cooling tower does not work for a long time, the water pump needs to be cleaned and kept in a good condition;G7dCooling tower noise reduction treatment manufacturer

  If the ambient temperature is below 0 ℃, all the internal liquid of the pump should be discharged to prevent freezing from causing the pump to burst.G7dCooling tower noise reduction treatment manufacturer

  4. Appropriate pipeline water should be added to the tower, and then the water pump should be operated to clean the pipeline After running for several days in this way, drain the pipeline water from the first run; Add soft water or distilled water again to the entire tower, and the tower can be used normallyG7dCooling tower noise reduction treatment manufacturer

  5. The water replenishment pipeline should be connected to the cooling tower water replenishment valve, and the amount of water replenishment should not be less than 2/3 of the total water volume (or determined by the automatic water replenishment valve). After operation, the spray water tank should be regularly cleaned to ensure its spraying effect.G7dCooling tower noise reduction treatment manufacturer

  Before starting the machine, please open all the valves that need to be opened, pull down the "pump on" and "fan on" buttons (the corresponding indicator lights are displayed in working state), and then check the pump's timely operation and whether the water flow is in the direction indicated by the arrow, whether the water pressure gauge is normal, and whether there are any leaks or unusual noises Then check the direction of the fan airflow, if there are any unusual vibration sounds Please resolve these identified issues immediately. If the problem exceeds your ability to handle, please contact our after-sales service department promptly.G7dCooling tower noise reduction treatment manufacturer

  7. Pull down the "pump off" and "fan mechanism" buttons, and the entire cooling tower will stop working To ensure the full safety of the electrical appliance, its air switch should be set to "off" to ensure that the power is completely cut off.G7dCooling tower noise reduction treatment manufacturer

  (Warning: Pumps are not allowed to start or operate without sufficient water flow.)G7dCooling tower noise reduction treatment manufacturer

  8. This soft water cooling system has its own temperature control device: it will automatically turn on the spray pump and fan according to customer needs (when its outlet temperature reaches its set top temperature), and it will also stop spraying water (when the outlet temperature cools down to the preset temperature).G7dCooling tower noise reduction treatment manufacturer

  9. For fan motors and pump motors, the electronic control system has an overload relay function.G7dCooling tower noise reduction treatment manufacturer

  10. Check the liquid level gauge on the water tank. If the water level is not enough, please replenish it in time.G7dCooling tower noise reduction treatment manufacturer

  Others, please follow the cooling tower maintenance manual for operation***G7dCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/694.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba