Precautions for the use of closed cooling towers

  Here are some issues to consider when choosing a closed cooling tower:ZJSCooling tower noise reduction treatment manufacturer

  1. The structural material of the cooling tower body should be stable, durable, corrosion-resistant, and accurately assembled.ZJSCooling tower noise reduction treatment manufacturer

  2. Uniform distribution of splashing water, minimal wall flow, reasonable equipment selection, and low risk of blockage.ZJSCooling tower noise reduction treatment manufacturer

  3. The type of filling material for cooling tower water spraying should meet the requirements of water quality and temperature.ZJSCooling tower noise reduction treatment manufacturer

  4. Fan matching to ensure long-term normal operation, no abnormal vibration and noise, blade water corrosion resistance, and sufficient strength. The installation angle of the fan blades can be adjusted, but ensure that the angle is consistent, and the motor current should not exceed the rated current of the motor.ZJSCooling tower noise reduction treatment manufacturer

  5. Low power consumption, low cost, small and medium-sized steel glass cooling towers also require high-quality light.ZJSCooling tower noise reduction treatment manufacturer

  6. Cooling towers should try to avoid thermal layout, exhaust and smoke, and chemical substances around piles as much as possible.ZJSCooling tower noise reduction treatment manufacturer

  7. The distance between cooling towers or towers and other buildings, in addition to considering the ventilation requirements of the tower and the mutual influence between the tower and the building, should also take into account the fire and explosion safety distance of the building, as well as the requirements for the construction and maintenance of cooling towers.ZJSCooling tower noise reduction treatment manufacturer

  8. The cooling tower of the intake duct rotates 90 °, 180 °, and 270 °.ZJSCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/686.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba