What are the methods to reduce the occurrence rate of cooling tower failures?

Author:Trlon  Views:  Time:2025-09-17
What are the methods to reduce the occurrence rate of cooling tower failures?

  A cooling tower is a large-scale cooling equipment that uses water as a circulating coolant. This equipment can absorb a large amount of heat through cold water, and then evaporate it through water; Releasing hot air has achieved the purpose of cooling down. Therefore, cooling towers have been widely used in many places, such as air conditioning cooling, refrigeration, and plastic chemical industries.fHZCooling tower noise reduction treatment manufacturer

  1. When the quality of circulating water and supplementary water is poor, water quality stabilization measures should be taken, side filters should be installed, and if necessary, sterilization and algae control measures should be taken.fHZCooling tower noise reduction treatment manufacturer

  2. Fiberglass is a combustible material, so it is known that open flames must not be used during maintenance of this cooling tower. If open flames are used, corresponding safety measures must be taken, and approval from the fire and safety departments must be obtained. There must be dedicated firefighters and fire-fighting facilities present.fHZCooling tower noise reduction treatment manufacturer

  3. Before the operation of the fan, motor, and reducer, they must be checked according to the corresponding product manual, especially the motor wiring, which should be wired according to the wiring diagram provided by the motor factory. Sometimes, inconsistent statements from all parties can easily cause wiring errors. Start up after meeting the requirements, starting sequence from low speed to high speed. After installing the blade angle according to the specified value of the sample, if the high-speed operating current exceeds the rated value, the machine should be stopped immediately and contact the Chongqing cooling tower manufacturer immediately.fHZCooling tower noise reduction treatment manufacturer

  4. The reducer should regularly check the oil level on the oil gauge. It is recommended to use 22-28 hyperbolic gear oil or 90-120 industrial gear oil as lubricating oil, and use high viscosity oil during the summer season. After the first 20 days of operation, drain the oil and replace it with new oil.fHZCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/675.html