Factors and solutions for water leakage in cooling tower water heaters

Author:  Views:  Time:2025-09-19
Factors and solutions for water leakage in cooling tower water heaters

  Leakage of cooling water heaters is a common problem, which not only causes waste of water resources and increases operating costs, but also may lead to safety hazards such as electrical equipment short circuits, structural corrosion, or winter icing. The following are the main factors causing water leakage in water distributors and corresponding solutions.ROfCooling tower noise reduction treatment manufacturer

  1、 Analysis of Leakage FactorsROfCooling tower noise reduction treatment manufacturer

  Nozzle or water distribution pipeline ruptureROfCooling tower noise reduction treatment manufacturer

  The reason is that the plastic material has aged and become brittle, and has been impacted by external forces. Improper installation has led to stress concentration, and in winter, it freezes and expandsROfCooling tower noise reduction treatment manufacturer

  Loose or damaged connectorsROfCooling tower noise reduction treatment manufacturer

  Reason: Loose or detached joints, threaded connections, U-shaped clamps, etc. between pipelines due to vibration, thermal expansion and contraction, or improper installation, or aging and damage of sealing ringsROfCooling tower noise reduction treatment manufacturer

  Bearing or seal failure of rotary water distributorROfCooling tower noise reduction treatment manufacturer

  Reason: Bearing wear leads to eccentric swinging of the main shaft, aging, wear or damage of seals by impurities, resulting in water leakage at the rotating jointROfCooling tower noise reduction treatment manufacturer

  Deformation of water distribution tray or main pipeROfCooling tower noise reduction treatment manufacturer

  Reason: Material aging, uneven heating, or external pressure can cause distortion and deformation of pipelines or water distribution trays, resulting in gaps at the interfaceROfCooling tower noise reduction treatment manufacturer

  Loose connection between nozzle and pipelineROfCooling tower noise reduction treatment manufacturer

  Reason: The nozzle is screwed in too tightly, causing the thread to slip, or not tightened, resulting in looseness and water leakageROfCooling tower noise reduction treatment manufacturer

  Corrosion or blockage caused by water quality issues leading to ruptureROfCooling tower noise reduction treatment manufacturer

  The high chloride ion content or abnormal pH value in the water can cause corrosion and perforation of metal components, leading to severe blockage and local high pressure causing ruptureROfCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/680.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba