Steps for cleaning the cooling tower fan of central air conditioning

Author:Trlon  Views:  Time:2021-10-14
Steps for cleaning the cooling tower fan of central air conditioning

  Trlon air conditioner summarizes the steps for cleaning the central air conditioning cooling tower fan as followski7Cooling tower noise reduction treatment manufacturer

  1. Before cleaningki7Cooling tower noise reduction treatment manufacturer

  Do a good job in the maintenance of corridors and walls, and check records: check whether the fan coil motor is operating normally, whether the unit is running abnormally, whether the filter is intact, whether the fin is damaged, the water inlet and outlet soft connection, valves, filters And heat preservation, promptly notify the above record of the above project manager in writingki7Cooling tower noise reduction treatment manufacturer

  2, stopki7Cooling tower noise reduction treatment manufacturer

  Turn off the power supply of the fan coil unit, and the fan coil unit wire is insulated to ensure that there is no leakage during the construction and the cleaning process of the construction safety.ki7Cooling tower noise reduction treatment manufacturer

  3, clean the filterki7Cooling tower noise reduction treatment manufacturer

  The metal is rinsed with clean water through the wire mesh, glass and fiber filter. If there is a particularly difficult stain to stick to it, soak it with a neutral detergent solution with a warm aqueous solution concentration to completely and effectively remove the stains on the fiber. Wipe the filter frame with a towel and detergent, and then rinse the environment with our clean water.ki7Cooling tower noise reduction treatment manufacturer

  4. Cleaning the fanki7Cooling tower noise reduction treatment manufacturer

  The dust on the outside of the fan is mainly absorbed by the vacuum cleaner. The dust attached to the impeller cannot be cleaned by the vacuum cleaner. Then use a brush and then wipe the dust under the brush with a damp cloth until there is no dust on the surface of the impeller. Wipe the fan shell and bracket with water, and clean with lotion and water when there are stubborn stains.ki7Cooling tower noise reduction treatment manufacturer

  5. Cleaning the motorki7Cooling tower noise reduction treatment manufacturer

  The motor film is washed with water before wrapping the electrical junction box, in order to avoid short circuit due to water. Clean the main shell and support of the washing machine, vacuum the left surface with a vacuum cleaner, and wipe with a rag until the support shell is clean and bright. After the washing machine is finished, remove the transparent plastic film of the upper junction box. In the case of electrical faults found in the inspection, it should be recorded and repaired or replaced in time.ki7Cooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/529.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba