Precautions for testing after installing a closed cooling tower

Author:  Views:  Time:2025-10-13
Precautions for testing after installing a closed cooling tower

  Precautions for testing after installing a closed cooling towerNTzCooling tower noise reduction treatment manufacturer

  After the installation of a closed cooling tower, it cannot operate. There are many things to pay attention to, because if not careful, other problems may occur. What should be noted after installing a closed cooling tower?NTzCooling tower noise reduction treatment manufacturer

  1. Level the cooling tower legs with the foundation, and then firmly weld or place them on the foundation embedded plate.NTzCooling tower noise reduction treatment manufacturer

  2. Clean the debris and dust at the gap between the enclosed cooling tower and the packing, and fill the transmission components such as the cooling tower reducer with lubricating oil.NTzCooling tower noise reduction treatment manufacturer

  3. Check if the screws on the tower, shell, and other parts are loose.NTzCooling tower noise reduction treatment manufacturer

  4. Adjust the fan angle according to the temperature difference requirements of the circulating water.NTzCooling tower noise reduction treatment manufacturer

  5. The fan of the closed cooling tower should rotate clockwise and must not be reversed. Before starting the cooling tower, check if the voltage is stable and if there is a phase loss. It is strictly prohibited to turn on the cooling tower motor when there is a phase loss or oil shortage in the reducer.NTzCooling tower noise reduction treatment manufacturer

  Is closed cooling tower expensive?

  Due to the market providing new options for cooling towers, if you want to gain more advantages on different equipment, as a closed cooling tower, you must pay a higher price. From a cost perspective, closed cooling towers are more expensive than traditional cooling towers, but the effectiveness and efficiency of traditional cooling towers are different, so we can consider choosing them.NTzCooling tower noise reduction treatment manufacturer

  Closed cooling towers are very popular now, but I don't know if there will be other new cooling towers in the future development process that are not closed cooling towers. At least from the current situation, closed cooling towers can play a huge role in the next five years or longer. But it is currently unclear what will happen in the future.NTzCooling tower noise reduction treatment manufacturer

  Many people want to know if the price of a closed cooling tower is expensive. In fact, compared to traditional cooling towers, the price of a closed cooling tower is slightly higher, with almost no significant difference. But the difference is that when using a closed cooling tower, the purity of the cooling medium can be guaranteed.NTzCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/709.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba