What is the difference in principle between open cooling towers and closed cooling towers?

Author:  Views:  Time:2025-10-22
What is the difference in principle between open cooling towers and closed cooling towers?

  What is the difference in principle between open cooling towers and closed cooling towers?u2iCooling tower noise reduction treatment manufacturer

  1、 Cooling principle of open cooling tower

  The cooling principle of the open cooling tower is to spray the circulating water on the glass fiber filler in the form of spray, and then heat exchange is achieved through the contact of water and air, and then the fan drives the air circulation in the tower to bring out the hot air after heat exchange with water, so as to achieve the cooling effect.u2iCooling tower noise reduction treatment manufacturer

  From the actual situation, we can find that the cooling method of open cooling tower, even if the initial investment is relatively small, consumes a lot of water and electricity, which means the operating cost is very high.u2iCooling tower noise reduction treatment manufacturer

  2、 Cooling principle of closed cooling tower

  A closed cooling tower does not require packing during the cooling process, and its main core component is a copper tube surface cooler. Simply put, it is two loop processes, namely the inner loop and the outer loop.u2iCooling tower noise reduction treatment manufacturer

  We can briefly introduce the two circulation processes of closed cooling towers as follows:u2iCooling tower noise reduction treatment manufacturer

  Internal circulation: Connect with the target device to form a closed circulation system (with soft water as the circulating medium). Cooling the target device by transferring the heat from the target device to the cooling unit.u2iCooling tower noise reduction treatment manufacturer

  External circulation: In the cooling tower, it cools down the cooling tower itself. Not in contact with the internal circulating water phase, only through the copper tube surface cooler in the cooling tower for heat exchange and dissipation. Under this cooling method, the operation of the motor is set according to the water temperature through automatic control.u2iCooling tower noise reduction treatment manufacturer

  Due to the relatively high ambient temperatures in spring and summer, it is necessary for two cycles of a closed cooling tower to be carried out simultaneously in order to cool down. On the contrary, the temperature in autumn and winter is not too high, and usually, we only need one internal cycle to complete the cooling process.u2iCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/737.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba