Key points to note before operating the cooling tower 1. During installation, please refer to the "Pipeline Installation Instructions" and select the appropriate pipeline length, number of gate valves, number of bends, links, direct pipe joints, and so on Other hose fittings should be determined based on the actual situation in the required fiel
Initial and Seasonal Launch Before turning on the device power, check the following: 1. Remove all debris, such as leaves and garbage on the style fence. 2. Rinse the spray tank to remove sediment and dirt. 3. Check if the mechanical float valve is operating flexibly. 4. Check the nozzles of the water distribution system and clean them if necessary. C
Maintenance and upkeep of cooling towers during operation As an important cooling equipment, the cooling tower should be maintained and managed by a dedicated person, with maintenance and observation of its operation. It is important to regularly pay attention to changes in current and water temperature, and to check for any abnormal sounds. If there are
Suggestions for long-term shutdown of cooling towers When the system is shut down for a long time, the following operations should be performed. The water in the evaporative cooling equipment should be drained. 2. Rinse the spray tank clean. 3. The drainage of the cold water tray should be kept open. 4. The adjustment bolts of the ventilation fan bear
Cooling tower heat sink is a device used to dissipate heat from electronic components that are prone to heat generation in electrical appliances. It is often made of aluminum alloy, brass, or bronze in the form of plates, sheets, or multiple sheets. For example, large heat sinks are required for the central processing unit (CPU) in a computer, as well as f
The thermal calculation of a cooling tower has two purposes. Firstly, given the water and heat loads, the required area of the cooling tower can be determined based on the cooling requirements under specific meteorological conditions; The second is to know the various conditions of the cooling tower and calculate the cooled water temperature under specific
In the normal operation of the chiller unit, if unexpected equipment failures or sudden power outages, water cuts, or other special situations occur due to external reasons, which may cause harm to the unit, emergency measures should be taken to stop the unit in the shortest possible time, that is, emergency shutdown. The general procedure for emergency sh
The cold water collection tank should maintain its water depth to avoid cavitation. The freeboard height of the collection tank is 15-30cm, and the effective volume of the tank is below. The water level of the tank should be maintained at a certain level, otherwise the replenishment valve needs to be adjusted. For cross flow cooling towers, if the operatin
Here are some issues to consider when choosing a closed cooling tower: 1. The structural material of the cooling tower body should be stable, durable, corrosion-resistant, and accurately assembled. 2. Uniform distribution of splashing water, minimal wall flow, reasonable equipment selection, and low risk of blockage. 3. The type of filling material for
Cooling fan: can be made into fiberglass, carbon steel spray coating, stainless steel according to different user requirements; Ordinary, variable frequency high air volume, low-noise fan. 1. Dehydrator: To save precious water resources. A high-efficiency dehydrator has been installed at the bottom of the fan, effectively controlling the loss of water flo