Premature damage to cooling tower packing can directly reduce heat exchange efficiency, increase energy consumption and replacement costs. Its damage is often related to improper material selection, water pollution, lack of maintenance, abnormal operation, etc. Prevention should be taken from multiple dimensions: 1、 Accurate selection: matching working co
Dust accumulation on cooling tower fan blades can directly lead to an increase in power consumption by changing the operating conditions of the fan and increasing equipment load. The specific impact mechanism and degree are as follows: 1、 Disrupting the airflow structure and increasing wind resistance losses The accumulation of dust on the surface of the
Leakage of cooling water heaters is a common problem, which not only causes waste of water resources and increases operating costs, but also may lead to safety hazards such as electrical equipment short circuits, structural corrosion, or winter icing. The following are the main factors causing water leakage in water distributors and corresponding solutions
Advantages and disadvantages of various evaporative condensers According to the different cooling media and cooling methods, condensers are divided into three categories: water-cooled condensers, air-cooled condensers, and evaporative condensers. Evaporative condenser: integrates condenser, mercury water, cooling tower, and circulating water tank. Compac
The difference between evaporative condenser and cooling tower: 1. Evaporative condenser Evaporative condenser is a heat exchange device used for cooling cold storage, which is composed of components such as fans, coils, heat exchange fins, and boxes. Also known as evaporative cooling or condenser, it is a device that gradually cools the refrigerant insi
Construction procedures Cutting and polishing of the evaporative condenser pipeline after ammonia release - removal and placement of the old evaporative condenser - hoisting of the new evaporative condenser - connection of the evaporative condenser pipeline - anti-corrosion painting of pipeline welds - removal of electrical parts - threading of electrical
Closed cooling tower, also known as closed cooling tower or enclosed cooling tower, is a type of cooling tower that places a tube heat exchanger inside the tower and ensures cooling effect through heat exchange between circulating air, sprayed water outside the tube, and circulating water inside the tube. Advantages of closed cooling tower: 1. The pressu
A cooling tower is a large-scale cooling equipment that uses water as a circulating coolant. This equipment can absorb a large amount of heat through cold water, and then evaporate it through water; Releasing hot air has achieved the purpose of cooling down. Therefore, cooling towers have been widely used in many places, such as air conditioning cooling, r
The floating rate should be calculated according to Appendix F of "Mechanical Ventilation Cooling Towers Part 1: Small and Medium sized Open Cooling Towers" (GB/T 7190.1-2018). Drift rate: the ratio of the amount of water that floats out of the cooling tower outlet to the amount of water that enters the tower per unit time. measuring point arran
A cooling tower is a large-scale cooling equipment that uses water as a circulating coolant. This equipment can absorb a large amount of heat through cold water, and then evaporate it through water; Releasing hot air has achieved the purpose of cooling down. Therefore, cooling towers have been widely used in many places, such as air conditioning cooling, r