Trlon air conditioner manufacturers have silent cooling towers, closed cooling towers and cooling tower noise reduction, maintenance and transformation services.
National Service Hotline National Service Hotline:

4008-8383-95

Your current location:HOME > Product > Square Cooling Tower

Square Cooling Tower

Square countercurrent cooling tower equipment

Author:Trlon Views: Time:2020-08-27
Square countercurrent cooling tower equipment

  A cooling tower in which water flows down vertically in a direction opposite to the flow of water. A device for cooling water. Water in its heat exchange with the air through the mass exchange, resulting in a drop in the temperature of the water.ngMCooling tower noise reduction treatment manufacturer

  Countercurrent and cross flow

  1) According to the noise level:ngMCooling tower noise reduction treatment manufacturer

  Common type (P), low noise type (D), ultra-low noise type (C), industrial type (G)ngMCooling tower noise reduction treatment manufacturer

  2) According to the structure of the tower, there are square tower and round tower.

  1) the cooling tower should be high cooling efficiency, energy saving, low noise, light weight, small volume, long life, simple installation and maintenance, less floating water.ngMCooling tower noise reduction treatment manufacturer

  2) The selected finished cooling tower shall comply with "Glass Fiber Reinforced Plastics Cooling Towers - Part 2: Large Glass Fiber Reinforced Plastics"Cooling tower GB 7190.2-1997 requirements.ngMCooling tower noise reduction treatment manufacturer

  3) If there is a large gap between the design working condition and the standard working condition of the low-temperature cooling tower, the thermal performance curve provided in the product sample should be selected.ngMCooling tower noise reduction treatment manufacturer

  4) If the thermal performance curve provided by the manufacturer is collated and drawn by the test data of the simulation tower, the test data of the simulation tower should be corrected according to the difference between the test conditions of the simulation tower and the operating conditions of the design tower, with a correction coefficient of 0.80 ~ 1.00.ngMCooling tower noise reduction treatment manufacturer

  5) The location of the cooling tower should be kept at a certain distance from the building, and avoid placing it near the heat source, waste gas and flue gas outlet.ngMCooling tower noise reduction treatment manufacturer

  If the above requirements cannot be met, technical measures shall be taken and the thermal performance shall be checked at the same time.ngMCooling tower noise reduction treatment manufacturer

  6) The circulating cooling water should be free of oil and substances that may dissolve FRP, and the turbidity of the water should not be greater than 50mg/L. And shall adoptngMCooling tower noise reduction treatment manufacturer

  Algae removal and water quality stabilization measures.ngMCooling tower noise reduction treatment manufacturer

  7) The design circulating water should not exceed the rated water of the finished cooling tower. If the circulating water is less than 80% of the rated water,ngMCooling tower noise reduction treatment manufacturer

  The selected cooling tower water distribution system shall be checked.ngMCooling tower noise reduction treatment manufacturer

  8) The number of cooling towers should be matched with the number of air conditioning refrigeration units.ngMCooling tower noise reduction treatment manufacturer

  9) According to the noise control requirements of civil buildings in "Urban Area Environmental Noise Standard" GB3096-1993, it can pass the noisengMCooling tower noise reduction treatment manufacturer

  To calculate the space attenuation, select low noise or ultra-low noise cooling tower, if still can not meet the environmental noise index, should be addedngMCooling tower noise reduction treatment manufacturer

  Then take noise reduction measures.ngMCooling tower noise reduction treatment manufacturer

  10) Roof fire hydrants and washing facilities should be installed near the cooling tower to serve as fire extinguishing and washing water filler and deposition in the tower bodyngMCooling tower noise reduction treatment manufacturer

  The content with.ngMCooling tower noise reduction treatment manufacturer

  11) The material of the cooling tower should be flame retardant and meet the requirements of fire prevention. It should be indicated in the main equipment table and the order contract.ngMCooling tower noise reduction treatment manufacturer

  12) When choosing the finished cooling tower, attention should be paid to the coordination and coordination of electrical control.ngMCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/product/359.html

Product

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba